Model library · Thermador Ventilation Hood

UCVM36FS

Thermador UCVM36FS

What we most often repair on units like this

  1. Rotary knob that spins freely or skips a position
  2. Weak inlet draw across a wide cooktop
  3. Cassette filter with baked-on grease
  4. Rattling inside the cabinet from the blower housing
  5. Poor results in recirculation mode with a spent filter

This one is for the wider cooktop. At 36 1/2 inches across and 34 1/2 inches tall, the UCVM36FS rises behind the burners and has to reach the outer edges of a 36-inch top with only 3 3/4 inches of thickness. Edge burners sit farthest from the blower, so steam from them is the first to get past.

It uses three rotary switches and has no damper, filter reminder, delay shut off or heat lamp. In practice that makes diagnosis direct: speed one, two and three should each give a different sound and draw, and if one does not, the switch or the motor winding is the issue.

We look at the aluminum-frame cassette filter first, then the duct. If it is set to recirculate, a clogged outlet is a typical cause of poor performance. Thermador lists the model as no longer available with no successor given.

Key features

  • 36 1/2-inch downdraft hood
  • Overall size 34 1/2H×36 1/2W×3 3/4D in
  • Built-in; ducted, convertible to recirculation mode
  • Rotary switch controls with 3 fan speeds
  • Cassette filter with aluminum frame
  • No damper, filter reminder, delay shut off or heat lamp
→Codes

Codes this model may display

UCVM36FSUCVM36FS questions
Do the outer burners get less coverage?

Often, yes, since the intake is in the middle. A clean filter and a clear duct give the best result the design allows. It helps to set pots on the inner burners for tall cookware.

One speed gives no airflow. What is wrong?

Either the rotary switch lost contact in that position or the motor winding has failed. We measure at the blower to tell which. Replacing a switch is a modest job, a motor much larger.

Can I convert it to recirculation myself?

It is designed to be convertible, but the outlet path and filter must be right. We can set it up and check the airflow. Please let us do it.

Request service

Schedule service for your UCVM36FS

Request a visit online in about a minute or phone our coordinators. Close-in neighborhoods often see a same-day slot; the outer counties usually get the next day across Houston.