Thermador Cooktop F3 on Older CIT365GB-Series Induction Units: Cooking Sensor Too Hot (Legacy Meaning)
F3 on the older Masterpiece generation means the cooking sensor is too hot. Models named in the manual are CIT304GB, CIT304GM, CIT365GB, CIT365GM and CIS365GB, and newer Thermador induction cooktops do not use this table. You…
- Code
- F3
- Appliance
- Cooktop
- Brand
- Thermador
- Warranty
- 30-day workmanship
What F3 means
F3 on the older Masterpiece generation means the cooking sensor is too hot. Models named in the manual are CIT304GB, CIT304GM, CIT365GB, CIT365GM and CIS365GB, and newer Thermador induction cooktops do not use this table. You see F3 while the sensor probe sits in a very hot pan or on a hot surface, and the cooktop stops using it until it has cooled.
Usual causes of F3
- Sensor probe left in a very hot pan or on a hot zone
- Sensor still carrying heat from earlier cooking
- Sensor temperature reading stuck high after it cooled
1. Remove the pan from the element. 2. Take out the cooking sensor and set it on a heat-safe surface. 3. Press the cooking sensor key, then press any symbol. 4. F3 disappears when the sensor has cooled. If it stays after a long wait, stop using the sensor.
- The sensor and its socket sit close to live power electronics.
- A sensor reading stuck high needs testing against a known value.
- We quote in writing before any older-unit repair.
Technical reference
- Code
- F3
- Appliance
- Thermador cooktop
- Maker documentation
- Thermador owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Thermador.
More Cooktop codes
What exactly is the cooking sensor?
It is the probe this older generation uses for temperature-controlled cooking. F3 tells you the sensor itself is too hot, so remove the pan and give the sensor time to cool.
Is F3 the same on new Thermador cooktops?
No. This code belongs to the older CIT365GB-era table. Newer Thermador induction cooktops use different messages for different problems, so compare by model number.
F3 appeared after a long simmer. Is that normal?
It can be. Long cooking at high heat can warm the sensor past its limit. Let it cool and try again; if F3 appears with a cold sensor, book service.