What we most often repair on units like this

  1. One gas oven does not light while its partner works
  2. The griddle, or a burner, refuses to ignite
  3. Keep Warm cannot hold a steady low heat
  4. Self-clean cycle that ends early on one oven or both
  5. Home Connect app that will not pair

Every heat source on the PRG486WDG runs on gas, from the burners to the igniter in each oven. Thermador built it in the Pro Grand commercial-depth line at 48 inches, with two burners and a griddle on top and two separate ovens beneath: 3 cu ft for the primary, 1.3 cu ft for the secondary on the left. Its PRD-prefixed cousins use electric ovens instead. Our first step on any call is isolating the specific burner or oven that is affected.

Each oven runs its own Self Clean cycle and its own Keep Warm mode. A stalled clean cycle, or a Keep Warm temperature that wanders, therefore has to be tied to one cavity before we dig further.

If the griddle, a burner, or either oven will not light reliably and gas is in the air, close the range’s gas valve before any other troubleshooting. As the range ages, igniters and gaskets deserve the first look.

Key features

  • Professional Range running only on gas, 48'' wide, commercial Pro Grand depth; two gas ovens share the body below one cooktop
  • Cooktop with a non-stick griddle and two open gas burners
  • Gas ovens, both: primary 3 cu ft (AHAM) offering 5 cooking modes, left-side secondary 1.3 cu ft offering 5 cooking modes
  • Self Clean included, and island trim ships with the range
  • 120V/20A hookup plus Home Connect WiFi
→Codes

Codes this model may display

PRG486WDGPRG486WDG questions
Both ovens on my PRG486WDG are gas. Can one work while the other does not?

Yes. Each oven has its own igniter and burner, so one can light while the other stays dark. We find out which cavity is affected before testing anything else.

Why does Keep Warm run too hot or too cold?

Keep Warm cycles the oven's gas burner at a low rate, so uneven heat usually points to the igniter or gas valve control on that cavity.

What do I do if the griddle will not light?

Close the gas valve at the range if you smell gas, then call us. The griddle's ignition is checked on its own, apart from the two burners.