Thermador Dishwasher E0105: Start-Up Check Rejects the Heating Circuit
Shortly after power-up the dishwasher halts and E0105 appears. On newer boards that count in four digits, this is Thermador's wording for the situation that older machines report as E04: during its own opening check, the…
- Code
- E0105
- Appliance
- Dishwasher
- Brand
- Thermador
- Warranty
- 30-day workmanship
What E0105 means
Shortly after power-up the dishwasher halts and E0105 appears. On newer boards that count in four digits, this is Thermador's wording for the situation that older machines report as E04: during its own opening check, the heating electronics returned a reading the board refuses to accept. Loading, detergent and the door play no part in it.
Usual causes of E0105
- A loose or corroded plug on the harness between the board and the heating circuit
- A heating-circuit part whose measured value sits outside the expected range
- A control board that can no longer interpret the heater circuit it is meant to watch
1. Leave all panels closed, since this is not an owner-level test. 2. Look on the door edge for the label and copy down the model number and the FD number. 3. Record E0105 exactly as displayed. 4. Phone us with those details; this number needs a support call, and we find the cause by testing on site.
- The area under test is wired at line voltage, so exploring it while the machine is energized invites injury.
- No reset procedure is published for this number, and cycling the power again only postpones the measurement a technician would take with a meter.
Technical reference
- Code
- E0105
- Appliance
- Thermador dishwasher
- Maker documentation
- Thermador owner manuals and support
- Checked
- October 2026
We read the code from the maker’s documentation and our own service work, and we do not reproduce the maker’s document. Always confirm the full model number before acting on a code. We are an independent repair company, not affiliated with Thermador.
More Dishwasher codes
The dishes still come out warm. Does that mean the heater is fine?
Not necessarily. The check may be rejecting the reading taken by the watching circuit rather than the element, and a meter on the board side is the way to tell them apart.
Does E0105 describe the same problem as E04?
Thermador words them identically, so we regard them as one problem displayed by two generations of control board. The approach to diagnosing it does not change.
Where does a technician begin?
With the harness plugs, because a poor contact is the cheapest explanation and quick to rule out. Next come readings across the heater circuit, and then the board itself.